PROJECTS COMPLETED 

SALAR CENTER BARKET MARKET MAIN BOULEVARD 

NEW GARDEN TOWN LAHORE 
It's a centrally air-conditioned building, high side building the capacity of airConditioning plant is 661-USSRT capacity water chiller which is powered by waste Heat of power generators and natural gas, air handing units, fan coils units and other Allied equipment like cooling towers, pumping station, piping and ducting etc. 

TULIP RIVER SIDE HOTEL, JEHLUM 

A centrally air-conditioned hotel, having capacity of 100 ussrt air-conditioning system. The air- conditioning system comprises of 100 USSRT capacity absorption type (BROAD) Water chiller, air handling units of different capacity, fan coils units and other allied Equipments like cooling tower, pipelines, pump station and other works. 

HEAD OFFICE BULIDING OF IZHAR (PVT).LTD 

A Centrally air-conditioned building at Main Boulevard, new garden town, Lahore. The 
Air-conditioning system comprises of one no 100-USSRT absorption type water chiller 
And allied equipments like cooling tower, pipelines and fan coil units.
 

ZAINAB TOWER, MODEL TOWN LINK ROAD, LAHORE 

It's a central air- conditioned multi stories commercial building absorption (Broad) Water chiller 661 USSRT x2 NO. Cooling towers, air - handling units, fan coils units, Piping station and other allied works and complete installation. 

GULBERG ARCADES, MAIN BOULEVARD GLUBERG, LAHORE 

It's a central air-conditioned multi stories commercial building. The air-conditioned System comprises of 1-no absorption (BROAD) water chillers each 330-USSRT each Cooling tower, air handling units, fan coil units, piping work, pump station, ducting Work etc.

IC SEMI-CONDUCTORS (PVT) LTD, LAB THATTO, HASSAN ABDAL. 

Complete installation of production area of ICS, (Pvt) Ltd. It is notable that it is a semi 
Govt. sector and very much critical clean areas. No area is below 100-clean room. The airConditioning system comprises of 3-no packaged type absorption water chillers of 165-USRT 
Capacity each along with air handling units, ducting, piping and other allied equipments. 

STANDARD CHARTED BANK, RAWALPINDI 

Supply and installation of air cooled chilled 100-USRT, A.HU, duct work, pipe work And other ailed work complete in all respects. 

LUCKY CEMENT KARACHI/ LUCKY CEMENT PEZU 

Supply and installation of self contained package type unit's different capacity 600-USSRT and complete duct work and related electrical work complete in all respects. 

CITI BANK GARDEN TOWN LAHORE 

Supply and installation of self contain package type units and floor standing Units, split units of different capacity 150-USRT complete in all respects
 
FATIMA MEMORIAL HOSPITAL 

Supply and installation of absorption chiller 50-USRT, AHU's with heapa filters, Ducting and piping work in all respects as joint venture with Mohata Engineering. 

AZGARD-9 

Installation of 250-USRT hot water absorption chiller, cooling tower, pump station Install with heat exchanger complete in all respects. 

AMJAD TEXTILE 

Supply and installation of HVAC works designing and supply chilled water fan Coils units for labs and offices. 

MAPLE LEAF CEMENT 

Installation of complete self contained package type units' different capacity 350-USRT and related electrical panel room and complete wiring. 

MEDI PAK PHARMACEUTICAL LAHORE 

Installation of 50- USRT air cooled chillers complete in all respect. 

PHARMA CARE LAHORE 

Installation of 100-USRT air cooled water chiller and duct work complete in all Respects. 

AZGARD-9 

Installation of 500-USRT gas fired absorption chiller, cooling tower, pump station Install with 20 no AHU, MS, pipe work and duct work with material complete in all respects. 

PACFIC PHARMA 

Installation of absorption chiller 500- USRT, ducting and piping work with metrical in All respects as joint venture with Mohata Engineering.

DHA Islamabad Overseas Main office(Rawat) 

Supply and installation of absorption chiller 2 no 100-USRT,, ducting and piping Work with metrical and 50 no F CU units in all respects as joint venture with Mohata Engineering. 

PARK PLAZA HOTELUS Chain 5 star (Lahore) 

Installation of 400-USRT gas fired absorption chiller 2 Nos. cooling tower, pump station Install with 7 no AHU, 143 No. FCU'S, MS, pipe work and duct work with material complete in all respects. 

 